DocumentCode
2982362
Title
High voltage, high frequency conversion transformer
Author
Kerfoot, Charles S. ; Greif, Milton J.
Author_Institution
Northrop Grumman, Baltimore, MD, USA
Volume
1
fYear
1997
fDate
27 Jul-1 Aug 1997
Firstpage
329
Abstract
A 25 kW, 15 kV output, 50 kHz transformer with 100 kV primary to secondary isolation is described. The transformer will be the central element of a resonant inverter. Six of these resonant inverter outputs will be connected in series to produce 90 kV for an airborne application. The transformer and high voltage will be in an SF6 atmosphere. Unique ceramic coil forms and insulating shells are used to minimize size
Keywords
ceramics; coils; high-frequency transformers; invertors; resonant power convertors; 100 kV; 15 kV; 25 kW; 50 kHz; 90 kV; SF6; SF6 atmosphere; airborne application; ceramic coil forms; high frequency conversion transformer; high voltage; insulating shells; primary to secondary isolation; resonant inverter; Ceramics; Corona; Costs; Frequency conversion; Power conditioning; Power transformer insulation; Resonant inverters; Stress; Thermal management; Transformer cores;