• DocumentCode
    2987823
  • Title

    Design of Multi-channel Ultrasonic Flowmeter Based on ARM

  • Author

    Yang, Jie ; Jiao, Haining

  • Author_Institution
    Sch. of Mech. & Electr. Eng., Jiangxi Univ. of Sci. & Technol., Ganzhou, China
  • fYear
    2010
  • fDate
    25-27 June 2010
  • Firstpage
    758
  • Lastpage
    761
  • Abstract
    A multi-channel ultrasonic flowmeter was designed in this paper which is composed of supersonic transducer, electron circuit, flow rate indication and integral calculation system. Based on the concept of liner concentration of coal logs in pipeline and characteristics of Doppler frequency drift of coal particles and coal logs moved in pipeline, the measuring method of supersonic wave and the transportation principle of coal slurry-coal log pipeline were discussed and a multi-channel ultrasonic flowmeter was designed for measuring the total quantity of coal transported by pipeline. The Doppler signal was measured and analyzed by using mixed-frequency technique and FFT, and some designed circuits and signal measurement process were also offered.
  • Keywords
    flowmeters; ultrasonic measurement; ARM; Doppler frequency drift; FFT; coal logs; coal particles; electron circuit; flow rate indication; integral calculation system; mixed-frequency technique; multi-channel ultrasonic flowmeter; supersonic transducer; Acoustic measurements; Acoustics; Doppler effect; Frequency measurement; Pipelines; Transducers; Ultrasonic variables measurement; ARM; Doppler effect; flowmeter; pipeline;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical and Control Engineering (ICECE), 2010 International Conference on
  • Conference_Location
    Wuhan
  • Print_ISBN
    978-1-4244-6880-5
  • Type

    conf

  • DOI
    10.1109/iCECE.2010.194
  • Filename
    5630269