• DocumentCode
    2995910
  • Title

    Calculating method of moisture in oil-paper insulation at arbitrary temperature

  • Author

    Zhou, L.J. ; Wu, G.N. ; Wang, Y.F. ; Tang, Hongying

  • Author_Institution
    Southwest Jiaotong Univ., Chengdu
  • fYear
    2007
  • fDate
    14-17 Oct. 2007
  • Firstpage
    723
  • Lastpage
    726
  • Abstract
    There are short of reports for the equilibrium moisture partition between oil and paper at arbitrary temperature, while it is very important, since it not only can be used to calculate the water in paper by the water in oil under equilibrium conditions, but also is the basis of studying the moisture partition in oil-paper under disequilibrium conditions. In this paper, an approach surface on basis of approaching parameters curves about the relations of the temperature, the moisture in oil, and the moisture in paper is proposed, according to which, the equilibrium moisture partition curves in oil-paper insulation at arbitrary temperatures are obtained using the existed curves under different temperatures. The method is validated by comparing the calculated curve experiment data having been published.
  • Keywords
    moisture; paper; transformer oil; equilibrium moisture partition curves; oil-paper insulation; Circuit faults; Dielectrics and electrical insulation; Educational institutions; Humidity; IEC standards; Moisture measurement; Oil insulation; Petroleum; Power transformer insulation; Temperature; Approach surface; Equilibrium Moisture Partition; Oil-paper insulation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena, 2007. CEIDP 2007. Annual Report - Conference on
  • Conference_Location
    Vancouver, BC
  • Print_ISBN
    978-1-4244-1482-6
  • Electronic_ISBN
    978-1-4244-1482-6
  • Type

    conf

  • DOI
    10.1109/CEIDP.2007.4451510
  • Filename
    4451510