DocumentCode
2998423
Title
SVPWM method with the averaged pulse length versus conventional modulation method
Author
Baskys, A. ; Bleizgys, V. ; Gobis, V.
Author_Institution
Dept. of Comput. Eng., VGTU, Vilnius, Lithuania
fYear
2010
fDate
4-6 Oct. 2010
Firstpage
321
Lastpage
322
Abstract
The efficiency of the AC induction motor used in the variable speed drive fed by the three-phase AC voltage formed using developed by authors Space Vector Pulse Width Modulation (SVPWM) method with the averaged pulse length has been investigated. The obtained results are compared with the results gained using a conventional SVPWM method. They show that the SVPWM method with the averaged pulse length provides higher motor efficiency as compared to the case when a conventional SVPWM method is employed.
Keywords
PWM power convertors; induction motor drives; variable speed drives; AC induction motor; SVPWM method; averaged pulse length; space vector pulse width modulation; three-phase AC voltage; variable speed drive; Harmonic analysis; Induction motors; Inverters; Rotors; Space vector pulse width modulation; Temperature measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Electronics Conference (BEC), 2010 12th Biennial Baltic
Conference_Location
Tallinn
ISSN
1736-3705
Print_ISBN
978-1-4244-7356-4
Electronic_ISBN
1736-3705
Type
conf
DOI
10.1109/BEC.2010.5630790
Filename
5630790
Link To Document