DocumentCode
2998448
Title
20 kW 18-pulse diode converter - results of laboratory tests
Author
Mysiak, P.
Author_Institution
Dept. of Ship Autom., Gdynia Maritime Univ., Gdynia, Poland
fYear
2010
fDate
4-6 Oct. 2010
Firstpage
309
Lastpage
312
Abstract
The article presents the principle of operation of a coupled three-phase reactor (CTRλ) used applied in 18-pulse diode converter. Using sets of coupled three-phase power network reactors, the presented converter makes it possible to considerably reduce, at low cost, undesired higher harmonics in the power network current. Selected results of laboratory tests done on a 20kVA 18-pulse diode converter are included.
Keywords
diodes; power convertors; 18-pulse diode converter; coupled three-phase reactor; power 20 kW; power network current; Converters; Current; Harmonic analysis; Inductors; Laboratories; Rectifiers; Voltage measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Electronics Conference (BEC), 2010 12th Biennial Baltic
Conference_Location
Tallinn
ISSN
1736-3705
Print_ISBN
978-1-4244-7356-4
Electronic_ISBN
1736-3705
Type
conf
DOI
10.1109/BEC.2010.5630791
Filename
5630791