• DocumentCode
    3004435
  • Title

    True RMS power detection with high dynamic range

  • Author

    Klahn, G.

  • Author_Institution
    MPD Technol. Inc., Hauppauge, NY, USA
  • Volume
    4
  • fYear
    1999
  • fDate
    13-19 June 1999
  • Firstpage
    1773
  • Abstract
    All communication systems require some form of output power reporting as a means to manage the power efficiency of the output spectrum. Traditionally, this task has been performed with diode detectors. Diode detectors are non-linear devices and require elaborate compensation techniques to linearize and operate as a true RMS (Root Mean Square) detector over a wide dynamic and temperature range. A true RMS power detection scheme has been developed, which has a 22 dB dynamic range with /spl plusmn/1 dB accuracy and operates over a temperature range of -40/spl deg/C to +80/spl deg/C.
  • Keywords
    microwave detectors; power measurement; -40 to 80 C; RMS power detector; communication system; dynamic range; temperature range; Circuits; Dynamic range; Envelope detectors; Radio frequency; Schottky diodes; Signal detection; Temperature dependence; Temperature distribution; Temperature sensors; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Symposium Digest, 1999 IEEE MTT-S International
  • Conference_Location
    Anaheim, CA, USA
  • Print_ISBN
    0-7803-5135-5
  • Type

    conf

  • DOI
    10.1109/MWSYM.1999.780315
  • Filename
    780315