• DocumentCode
    3009260
  • Title

    Camera calibration for 2.5-D X-ray metrology

  • Author

    Gupta, R. ; Noble, A. ; Hartley, R. ; Mundy, J. ; Schmitz, A.

  • Author_Institution
    Gen. Electr. Corp. Res. & Dev. Center, Schenectady, NY, USA
  • Volume
    3
  • fYear
    1995
  • fDate
    23-26 Oct 1995
  • Firstpage
    37
  • Abstract
    This paper presents a new methodology for camera calibration of stereo X-ray projections. The image acquisition systems typically used in nondestructive evaluation result in views that are orthographic along one image axis and perspective along the other. A camera model for this sensing geometry, called the linear pushbroom model, is described. Four methods of calibration, which make different assumptions about what is known about the camera parameters, are presented and compared
  • Keywords
    calibration; cameras; industrial control; nondestructive testing; radiography; robot vision; stereo image processing; 2.5D X-ray metrology; camera calibration; camera model; camera parameters; image acquisition systems; image axis; industrial parts; linear pushbroom model; nondestructive evaluation; robotic arm; sensing geometry; stereo X-ray projections; Calibration; Cameras; Detectors; Fixtures; Grippers; Metrology; Pixel; Robot kinematics; Sensor arrays; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Image Processing, 1995. Proceedings., International Conference on
  • Conference_Location
    Washington, DC
  • Print_ISBN
    0-8186-7310-9
  • Type

    conf

  • DOI
    10.1109/ICIP.1995.537574
  • Filename
    537574