  • Title

    A silicon IR-source and CO2-chamber for CO2 measurements

  • Author

    Kälvesten, E. ; Corman, T. ; Huiku, M. ; Weckström, K. ; Meriläinen, P. ; Stemme, G.

  • Author_Institution
    Dept. of Signals, Sensors & Syst., R. Inst. of Technol., Stockholm, Sweden
  • fYear
    1998
  • fDate
    25-29 Jan 1998
  • Firstpage
    69
  • Lastpage
    74
  • Abstract
    For the first time a silicon IR-source and CO2-chamber system for measurement of CO2 concentration is presented. This new miniaturized infrared sensor is specially designed for the measurement of respiratory gases present in patient airways during anaesthesia or intensive care. The IR-sensor assembly consists of an IR-source chip with two pairs of diagonally arranged IR-sources for the generation of two switched “sample” and reference beams. The gas filter chip is arranged with two CO2 chambers directly beneath the two reference sources. These chambers “pre-absorb” the reference beam at the CO2 wavelength band around 4.26 μm. The reference beam is needed for long term stability and for compensation against cuvette window contamination. The electrically modulated IR-sources consist of incandescent polysilicon filaments coated with silicon nitride across a 220 μm deep cavity. The CO2-chambers with a length of 1 mm are fabricated by silicon fusion and anodic bonding at a chosen CO2 pressure for optimal filter characteristics. Test measurements of the infrared sensor system show high CO2-sensitivity meaning that the stringent requirements for this respirator application can be reached
  • Keywords
    biomedical equipment; carbon compounds; chemical variables measurement; elemental semiconductors; infrared detectors; infrared sources; silicon; stability; 4.26 mum; CO2; CO2 chambers; CO2 concentration; CO2 measurement; CO2 pressure; CO2-chamber; CO2-sensitivity; IR-sensor assembly; IR-source chip; SN; Si; Si fusion; anaesthesia; anodic bonding; compensation; cuvette window contamination; diagonally arranged IR-sources; electrically modulated IR-sources; gas filter chip; incandescent polysilicon filaments; infrared sensor; intensive care; long term stability; measurement of respiratory gases; miniaturized infrared sensor; optimal filter characteristics; patient airways; reference beams; reference sources; respirator application; silicon IR-source; Assembly; Contamination; Filters; Gases; Infrared sensors; Pollution measurement; Semiconductor device measurement; Silicon; Stability; Time measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Micro Electro Mechanical Systems, 1998. MEMS 98. Proceedings., The Eleventh Annual International Workshop on
  • Conference_Location
    Heidelberg
  • ISSN
    1084-6999
  • Print_ISBN
    0-7803-4412-X
  • Type

    conf

  • DOI
    10.1109/MEMSYS.1998.659731
  • Filename
    659731