DocumentCode
3012111
Title
Triple loop modulation (TLM) for high reliability and efficiency in Power Factor Correction (PFC) system
Author
Tsai, Jen-Chieh ; Ni, Chia-Lung ; Chen, Chun-Yen ; Chen, Yi-Ting ; Chen, Chi-Lin ; Chen, Ke-Horng
Author_Institution
Institute of Electrical Control Engineering, National Chiao Tung University, Hsinchu, Taiwan
fYear
2012
fDate
20-23 May 2012
Firstpage
1191
Lastpage
1194
Abstract
Reliability of the Power Factor Correction (PFC) system was improved by fast transient response using the proposed triple loop modulation (TLM). Low bandwidth of less than 20 Hz that rejects AC source of 60/120 Hz coupling deteriorated system reliability in case of output load variation. The proposed TLM can automatically adjust bandwidth to rapidly increase or decrease inductor current in order to shorten transient response time. In steady state, system stability can be guaranteed by low-frequency compensation pole without being affected by TLM. The test circuit fabricated in VIS 500 V UHV LDMOS process demonstrated the performance of the highly-integrated PFC controller with the proposed TLM. Experimental results showed that the PFC system with TLM has high PF of 99%, high efficiency of 95%, and high power driving capability of about 90 W. The improvement in transient response is twofold faster than conventional PFC design with output load variation from 90W to 45 W and vice versa.
Keywords
Bandwidth; Capacitors; Modulation; Reliability; Time domain analysis; Time varying systems; Transient response; fast transient response; power factor correction (PFC); triple loop modulation (TLM);
fLanguage
English
Publisher
ieee
Conference_Titel
Circuits and Systems (ISCAS), 2012 IEEE International Symposium on
Conference_Location
Seoul, Korea (South)
ISSN
0271-4302
Print_ISBN
978-1-4673-0218-0
Type
conf
DOI
10.1109/ISCAS.2012.6271447