Abstract
The projection set in a helical computed tomography scan is inherently incomplete and inconsistent. This is caused by the constant patient translation during the data acquisition process. We present an interpolative algorithm using the projections acquired within 2π view angle. We compare the image quality of this algorithm with one of the best helical reconstruction algorithms available today and demonstrate its superior performance
Keywords
computerised tomography; data acquisition; image reconstruction; interpolation; medical image processing; 2π interpolative algorithm; 2π view angle; data acquisition; helical computed tomography scan; helical reconstruction algorithms; image quality; interpolative algorithm; patient translation; performance; projection set; Computed tomography; Helium; Interpolation; Sampling methods;