• DocumentCode
    3015742
  • Title

    Simulation and analysis of acoustical comfort in an Intensive Care Unit

  • Author

    Rhiana, Febi ; Sarwono, Joko ; Soelami, FX Nugroho

  • Author_Institution
    Dept. of Eng. Phys., Bandung Inst. of Technol., Bandung, Indonesia
  • fYear
    2011
  • fDate
    15-17 Nov. 2011
  • Firstpage
    352
  • Lastpage
    357
  • Abstract
    Acoustical comfort in a hospital is required for recovering process, improving quality of sleep, improving patient´s comfort factor, and also to enhance medical staff´s working quality. A research related to acoustical comfort was conducted at the Intensive Care Unit (ICU) Hospital in Bandung, Indonesia. Acoustic parameters that are discussed in this paper are definition-50 (D-50), sound pressure level (SPL), and reverberation time (T-30). These parameters are measured and modified by simulation, actual measurement, subjective observation, and passive acoustic recommendation. Data from simulation shows that both T-30 and D-50 values (especially in speech frequency) are just slightly around the standard value, while simulation and actual measurement show that SPL value is above the standard of 35 dBA. On the other hand, subjective observation shows that noise sources are dominated by speech (250Hz-1,000Hz) and intermittent noise from alarm (1,000Hz-2,000Hz). Recommendation was determined through simulation by changing/coating concrete wall with fiberglass board. After recommendation, the values for D-50 and T-30 are 17.6%-88.7% and 0.3s-1.0s, respectively. For SPL (and Leq) parameter, there is a decrease of 7.7dBA (in patient´s area) and 2.5dBA (in nurse´s area). Overall, D-50 parameter is increased while both T-30 and SPL parameters are decreased, which considered better for acoustic environment in a hospital.
  • Keywords
    acoustic intensity measurement; acoustic noise; architectural acoustics; reverberation; speech; acoustic environment; acoustic parameters; acoustical comfort; concrete wall; fiberglass board; frequency 250 Hz to 2000 Hz; hospital; intensive care unit; noise sources; reverberation time; sleep; sound pressure level; speech frequency; working quality; Acoustic measurements; Acoustics; Speech; acoustic simulation; definition-50 (D-50); intensive care unit; reverberation time (T-30); sound pressure level (SPL);
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation Control and Automation (ICA), 2011 2nd International Conference on
  • Conference_Location
    Bandung
  • Print_ISBN
    978-1-4577-1462-7
  • Type

    conf

  • DOI
    10.1109/ICA.2011.6130186
  • Filename
    6130186