DocumentCode
3028861
Title
Diagnosis of a Mixed Eccentricity Fault in a Squirrel-cage Three-phase Induction Motor using Time Stepping Finite Element Technique
Author
Faiz, Jawad ; Ebrahimi, B.M. ; Toliyat, H.A. ; Akin, B.
Author_Institution
Sch. of Electr. & Comput. Eng., Univ. of Tehran, Tehran
Volume
2
fYear
2007
fDate
3-5 May 2007
Firstpage
1446
Lastpage
1450
Abstract
In this paper time stepping finite element (TSFE) method is applied for diagnosis of a mixed eccentricity fault in a voltage-fed induction motor. In addition, influence of load fluctuation upon the degree of the mixed eccentricity fault, magnetic field and torque of faulty motor are investigated. It is shown that decrease of load causes higher current harmonic components around fundamental component, while this was previously related to the low degree of the fault.
Keywords
fault diagnosis; finite element analysis; machine testing; squirrel cage motors; torque; load fluctuation influence; magnetic field; mixed eccentricity fault diagnosis; motor torque; squirrel-cage three-phase induction motor; time stepping finite element technique; voltage-fed induction motor; Circuit faults; Fault diagnosis; Finite element methods; Fluctuations; Frequency; Induction motors; Mathematical model; Performance analysis; Saturation magnetization; Stator windings;