• DocumentCode
    303146
  • Title

    Measured performance of a high-power-density microfabricated transformer in a DC-DC converter

  • Author

    Sullivan, Charles R. ; Sanders, Seth R.

  • Author_Institution
    Dept. of Electr. Eng. & Comput. Sci., California Univ., Berkeley, CA, USA
  • Volume
    1
  • fYear
    1996
  • fDate
    23-27 Jun 1996
  • Firstpage
    287
  • Abstract
    Experimental measurements are reported on microfabricated power conversion transformers. A device fabricated using a simplified `sandwich´ process confirms predicted performance in an 8 MHz DC-DC power converter, where it achieves a power-handling density of 22.4 W/cm 2 at 61% efficiency. Preliminary test results are reported for transformers based on a closed-core design, which is expected to achieve higher efficiency
  • Keywords
    DC-DC power convertors; 61 percent; 8 MHz; DC-DC power converter; closed-core design; experimental measurements; microfabricated power conversion transformers; performance; power-handling density; sandwich fabrication process; Circuit testing; Conductors; Copper; DC-DC power converters; Fabrication; Magnetic cores; Magnetic flux; Power conversion; Power measurement; Transformer cores;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Specialists Conference, 1996. PESC '96 Record., 27th Annual IEEE
  • Conference_Location
    Baveno
  • ISSN
    0275-9306
  • Print_ISBN
    0-7803-3500-7
  • Type

    conf

  • DOI
    10.1109/PESC.1996.548594
  • Filename
    548594