• DocumentCode
    3046030
  • Title

    Thermal power plant dynamics identification

  • Author

    Kulessky, R. ; Nudelman, G. ; Hain, Y.

  • Author_Institution
    Israel Electr. Corp. Ltd., Haifa, Israel
  • Volume
    2
  • fYear
    1999
  • fDate
    2-4 Jun 1999
  • Firstpage
    843
  • Abstract
    Aspects of the process identifiability and accuracy of the frequency response identification are discussed for a two stage identification approach proposed by Kulessky et al. (1996, 1998) and Peer et al. (1997). A frequency region is defined in which accuracy of the frequency response identification from noise data reaches maximum. Besides, the requirement for a deterministic test signal is formulated from the identifiability point of view. Retrofit of two 75 MW boilers and 140 MW power unit modeling at IEC Power Station are fulfilled by implementation of this identification procedure, yielding satisfactory results
  • Keywords
    boilers; dynamics; frequency response; identification; thermal power stations; transfer functions; 140 MW; 75 MW; IEC Power Station; boilers; dynamics identification; frequency response; steam turbines; thermal power plant; transfer function; Control systems; Frequency response; Laplace equations; Open loop systems; Power generation; Power system modeling; Pressure control; Signal processing; Testing; Transfer functions;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    American Control Conference, 1999. Proceedings of the 1999
  • Conference_Location
    San Diego, CA
  • ISSN
    0743-1619
  • Print_ISBN
    0-7803-4990-3
  • Type

    conf

  • DOI
    10.1109/ACC.1999.783159
  • Filename
    783159