DocumentCode
3050959
Title
Partial discharge testing of components for low-voltage equipment at high frequencies
Author
Hund, R. ; Pfeiffer, W. ; Reinhard, H. ; Scheuerer, F.
Author_Institution
Tech. Hochschule Darmstadt, Germany
fYear
1990
fDate
28-31 Oct 1990
Firstpage
261
Lastpage
266
Abstract
The measurement of partial discharges (PDs) at high frequency working voltages is considered. It is shown how test voltages of rather high frequency (up to 100 kHz) with a maximum peak value of 6 kVp can be generated. The PD test method at these frequencies is also described. Test results for optocouplers and coated printed circuit boards (PCBs) are discussed
Keywords
electronic equipment testing; opto-isolators; partial discharges; printed circuit testing; 100 kHz; 6 kV; PCBs; PD test method; coated printed circuit boards; high frequency working voltages; low-voltage equipment; measurement of partial discharges; optocouplers; Character generation; Circuit testing; Dielectric loss measurement; Dielectrics and electrical insulation; Frequency; Oscilloscopes; Partial discharges; Power transformer insulation; Switched-mode power supply; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation and Dielectric Phenomena, 1990. Annual Report., Conference on
Conference_Location
Pocono Manor, PA
Type
conf
DOI
10.1109/CEIDP.1990.201352
Filename
201352
Link To Document