• DocumentCode
    3050959
  • Title

    Partial discharge testing of components for low-voltage equipment at high frequencies

  • Author

    Hund, R. ; Pfeiffer, W. ; Reinhard, H. ; Scheuerer, F.

  • Author_Institution
    Tech. Hochschule Darmstadt, Germany
  • fYear
    1990
  • fDate
    28-31 Oct 1990
  • Firstpage
    261
  • Lastpage
    266
  • Abstract
    The measurement of partial discharges (PDs) at high frequency working voltages is considered. It is shown how test voltages of rather high frequency (up to 100 kHz) with a maximum peak value of 6 kVp can be generated. The PD test method at these frequencies is also described. Test results for optocouplers and coated printed circuit boards (PCBs) are discussed
  • Keywords
    electronic equipment testing; opto-isolators; partial discharges; printed circuit testing; 100 kHz; 6 kV; PCBs; PD test method; coated printed circuit boards; high frequency working voltages; low-voltage equipment; measurement of partial discharges; optocouplers; Character generation; Circuit testing; Dielectric loss measurement; Dielectrics and electrical insulation; Frequency; Oscilloscopes; Partial discharges; Power transformer insulation; Switched-mode power supply; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena, 1990. Annual Report., Conference on
  • Conference_Location
    Pocono Manor, PA
  • Type

    conf

  • DOI
    10.1109/CEIDP.1990.201352
  • Filename
    201352