DocumentCode
3062111
Title
Deformation correction using Euclidean contour distance maps
Author
Verbeek, Fons J.
Author_Institution
Fac. of Appl. Phys., Delft Univ. of Technol., Netherlands
fYear
1992
fDate
30 Aug-3 Sep 1992
Firstpage
347
Lastpage
351
Abstract
Utilizes the Euclidean distance transform as a tool for shape analysis and description. The author shows effective use of some (new) properties of the vector distance transform in determining parameters for a two-step transform of a distorted image to its undistorted equivalent. The transform is based on the outer contour of the object of interest as present in the image
Keywords
image processing; transforms; Euclidean distance transform; distorted image; image processing; shape analysis; shape description; two-step transform; vector distance transform; Anatomy; Biological materials; Biomedical imaging; Embryo; Euclidean distance; Image reconstruction; Pattern recognition; Physics; Pixel; Shape;