• DocumentCode
    3062461
  • Title

    A reliability study of the new Back Strain Monitor based on clinical trials

  • Author

    Ronchi, A.J. ; Lech, M. ; Taylor, N.F. ; Cosic, I.

  • Author_Institution
    School of Electrical and Computer Engineering, RMIT University, GPO Box 2476V Melbourne Victoria 3001 Australia
  • fYear
    2008
  • fDate
    20-25 Aug. 2008
  • Firstpage
    693
  • Lastpage
    696
  • Abstract
    A new Back Strain Monitor (BSM) device has been developed in order to measure, record and analyze movements of the lower back. The purpose of this study was to examine the inter-tester and the intra-tester reliability of the movement measurements given by the BSM accelerometers, and compare it with the reliability of two other conventional measurement methods: the Double Inclinometer method (DI) and the Modified-Modified Schober (MMS) method. The clinical studies included 23 participants (16 males, 7 females) with no recent history of lower back pain, who wore the device during a combination of different anatomical movements (flexion, extension, left lateral flexion and right lateral flexion of the lumber spine). The tests were conducted by three therapists (testers). The reliability results for the BSM accelerometers clearly outperform the results obtained for the DI and the MMS methods. The inter-tester reliability gives the Intra-Class Correlation (ICC) value of 0.95 for the BSM flexion, 0.89 for the DI flexion and 0.74 for the MMS. The intra-tester reliability gives the ICC value of 0.99 for BSM flexion, 0.94 for DI flexion and 0.77 for the MMS. The BSM accelerometers were highly reliable in assessing back movements, measuring these movements with less error than the DI and MMS methods.
  • Keywords
    Accelerometers; Back; Capacitive sensors; Clinical trials; History; Monitoring; Motion measurement; Pain; Strain measurement; Testing; Acceleration; Adult; Back; Back Pain; Equipment Design; Equipment Failure Analysis; Female; Humans; Male; Monitoring, Ambulatory; Reproducibility of Results; Sensitivity and Specificity; Stress, Mechanical; Transducers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2008. EMBS 2008. 30th Annual International Conference of the IEEE
  • Conference_Location
    Vancouver, BC
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-1814-5
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/IEMBS.2008.4649247
  • Filename