    Non-circular multi-sector split-focus transducer for coagulation therapy

  • Author

    Umemura, S. ; Sasaki, K. ; Kawabata, K. ; Azuma, T.

  • Author_Institution
    Central Res. Lab., Hitachi Ltd., Kokubunji, Japan
  • Volume
    2
  • fYear
    2000
  • fDate
    36800
  • Firstpage
    1409
  • Abstract
    The split-focus approach has a potential to substantially improve the throughput of coagulation HIFU treatment through multiplying the volume of the focal zone without forming unwanted foci either in front or behind the focal plane. The ideal, theoretically simplest split focal field can be generated from a geometrically focused transducer with a circular aperture uniformly divided into many sectors. However, for an intracavitary transducer, a non-circular shape of aperture is usually needed to have a necessary aperture area within its allowed size. A theoretical consideration how to divide the aperture into many sectors for forming a relatively uniform temperature distribution in the focal zone was developed. A transrectal therapeutic transducer at 3 MHz with a rectangular aperture of 20×40 mm divided into eight sectors with,a geometric focal length of 30 mm was designed and fabricated based on the above consideration followed by the computer simulation of transient temperature distribution. It has been confirmed that significantly large lesion can be created even without tissue boiling if a spilt focus method is used with properly designed large number of sectors
  • Keywords
    biomedical transducers; biomedical ultrasonics; coagulation; hyperthermia; radiation therapy; temperature distribution; tumours; ultrasonic focusing; ultrasonic transducers; 20 mm; 3 MHz; 40 mm; bioheat transfer equation; blood perfusion rate; coagulation therapy; colon carcinomas; computer simulation; focal zone volume increase; geometrically focused transducer; intracavitary transducer; noncircular aperture; noncircular multisector split-focus transducer; power deposition; relatively uniform temperature distribution; split focal field; tissue ablation; transient temperature distribution; transrectal therapeutic transducer; Apertures; Coagulation; Frequency estimation; Heating; Medical treatment; Shape; Tellurium; Temperature distribution; Throughput; Ultrasonic transducers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 2000 IEEE
  • Conference_Location
    San Juan
  • ISSN
    1051-0117
  • Print_ISBN
    0-7803-6365-5
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2000.921586
  • Filename
    921586