DocumentCode
3094940
Title
Effect of scanning direction on the statistical parameters of ultrasonic signals backscattered from the annular pulley and tendon
Author
Yi-Hsun Lin ; Tai-Hua Yang ; Shyh-Hau Wang ; Fong-Chin Su
Author_Institution
Dept. of Comput. Sci. & Inf. Eng., Nat. Cheng Kung Univ., Tainan, Taiwan
fYear
2013
fDate
21-25 July 2013
Firstpage
409
Lastpage
412
Abstract
Previous studies have demonstrated that quantitative parameters estimated from backscattering signals are capable of characterizing pulley and tendon tissues for being applied to diagnose the trigger finger syndrome. Yet, the probability density functions (PDFs) of the envelope signals were found to vary significantly between those acquired from the transverse and sagittal views of samples. To extensively explore these effects, this study used a 30 MHz high-frequency ultrasound and theoretical considerations, to further comprehend the effect of the ultrasonic scanning direction on the estimated statistical parameters from the annular pulley and tendon. The ex vivo experiments began with the preparations of pulley and superficial digital flexor tendon (SDFT) excised from the first annular (A1) pulley region of cadavers. The tissue samples were then immersed in a saline solution tank. The ultrasound system was arranged to allow the scanning of tissues from the direction parallel to the fiber axis, at 0°, to that of perpendicular direction, at 90°, in which the increment of scanning angle is 5°. Statistical parameters, including Nakagami parameter (m) and scaling parameter, were estimated from regions of the acquired backscattering signals. Histological slices were also made for results verification. The scaling parameters associated with A1 pulley and SDFT of different scanning angles did not vary significantly; while those of the corresponding m was decreased significantly, as the scanning angle increased. The m of SDFT tended to decline with the increase of scanning angle faster than that of A1 pulley. Specifically, the m parameters of A1 pulley and SDFT decreased respectively from 1.06 ± 0.10 to 0.88 ± 0.07 and from 1.03 ± 0.06 to 0.78 ± 0.03. The empirical results are consistent with Nakagami statistical distribution, and which demonstrate that m could be applied to quantitatively assess to characterize the - DF of high-frequency ultrasonic envelopes from the A1 pulley and SDFT at various scanning angles.
Keywords
backscatter; biological tissues; biomedical ultrasonics; medical disorders; statistical distributions; ultrasonic scattering; A1 pulley; Nakagami parameter; Nakagami statistical distribution; PDF; SDFT; annular tendon; backscattering signals; cadavers; envelope signals; estimated statistical parameter; fiber axis; first annular pulley region; frequency 30 MHz; high-frequency ultrasonic envelopes; histological slices; m parameters; perpendicular direction; probability density functions; pulley tissues; quantitative parameter; sagittal views; saline solution tank; scaling parameter; scanning angle increment; superficial digital flexor tendon; tendon tissues; theoretical consideration; tissue scanning; transverse views; trigger finger syndrome; ultrasonic scanning direction; ultrasonic signal backscattering; ultrasound system; Acoustics; Nakagami distribution; Pulleys; Tendons; Thumb; Ultrasonic imaging; Nakagami parameter; high-frequency ultrasound; pulley; tendon; trigger finger;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium (IUS), 2013 IEEE International
Conference_Location
Prague
ISSN
1948-5719
Print_ISBN
978-1-4673-5684-8
Type
conf
DOI
10.1109/ULTSYM.2013.0106
Filename
6724958
Link To Document