• DocumentCode
    3096194
  • Title

    Resistance against external aggression for central tube submarine optical fiber cable

  • Author

    Hong-Xia Wang ; Hong-liang Liu ; Ying-jian Wang

  • Author_Institution
    Electron. Coll. of Eng., Naval Univ. of Eng., Wuhan, China
  • Volume
    3
  • fYear
    2011
  • fDate
    8-9 Sept. 2011
  • Firstpage
    175
  • Lastpage
    178
  • Abstract
    The central tube submarine optical fiber cables (SOFC) with double armors are recommended to lay in shallow water. However, they are often damaged by external aggression. The finite element method (FEM) models of two cable types, which are double-armored cable and single armored cable with two inner armors, are proposed in this paper. Crush and snag resistance performance of the cables are compared and analyzed. The distortion and strain of cable´s tube core are simulated by the FEM model. Simulation results verified that the performance of inner armored cable is better than that of double armored cable.
  • Keywords
    finite element analysis; optical cables; submarine cables; FEM model; SOFC; central tube submarine optical fiber cable; crush resistance; double-armored cable; external aggression; finite element method; single armored cable; snag resistance; Cable shielding; Communication cables; Electron tubes; Finite element methods; Optical fiber cables; Optical fiber communication; Steel; FEM model; crush resistance; distortion; snag; submarine optical fiber cables (SOFC);
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Engineering and Automation Conference (PEAM), 2011 IEEE
  • Conference_Location
    Wuhan
  • Print_ISBN
    978-1-4244-9691-4
  • Type

    conf

  • DOI
    10.1109/PEAM.2011.6135070
  • Filename
    6135070