Abstract
This paper describes a simple 2D model for the propagation of electro-magnetic (EM) pulses in human tissues. To assess the reliability of using this model for fast attenuation evaluation of UWB radar pulses in the body, the model is compared with a well known 3D FDTD numeric simulator using a simple multilayer geometry. Results from the 2D model were found in full accordance with the 3D one, allowing making a few considerations over the expected attenuation of UWB return echoes coming from the inner tissue interfaces in a typical medical UWB radar application.
Keywords
biological tissues; electromagnetic wave propagation; finite difference time-domain analysis; radar applications; radar cross-sections; radar detection; ultra wideband radar; 2D simple attenuation model; FDTD 3D simulator; UWB medical radar detection; UWB return echoes; electromagnetic pulse propagation; finite difference time-domain analysis; human tissue; multilayer geometry; Attenuation; Biological system modeling; Finite difference methods; Humans; Medical simulation; Nonhomogeneous media; Numerical simulation; Solid modeling; Time domain analysis; Ultra wideband radar; Attenuation model; FDTD; UWB; human tissues; medical radar;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultra-Wideband, 2008. ICUWB 2008. IEEE International Conference on
Conference_Location
Hannover
Print_ISBN
978-1-4244-2216-6
Electronic_ISBN
978-1-4244-1827-5
Type
conf
DOI
10.1109/ICUWB.2008.4653401
Filename
4653401
Link To Document