• DocumentCode
    3132824
  • Title

    Evaluating ATE-equipment for volume diagnosis

  • Author

    Arnold, Ralf ; Leininger, Andreas

  • Author_Institution
    Infineon Technol. AG, Munich
  • fYear
    2005
  • fDate
    8-8 Nov. 2005
  • Lastpage
    1075
  • Abstract
    Test data collection is increasingly seen as an important functionality of the ATE. The lack of clear specification parameters makes comparison of different ATE equipment with regard to data collection a difficult job. In this paper, the approach of Infineon Technologies is presented. Evaluation scenarios for measuring the performance of new ATE equipment regarding diagnosis data acquisition during production test are described. Evaluation results of "state-of-the-art" test equipment are compared and the deficiencies of today\´s test equipment are discussed compared to Infineons requirement "zero run time overhead"
  • Keywords
    automatic test equipment; data acquisition; production testing; ATE-equipment; diagnosis data acquisition; production test; volume diagnosis; Automatic testing; Built-in self-test; Data acquisition; Manufacturing; Monitoring; Production; Random access memory; Sections; System testing; Test equipment;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Test Conference, 2005. Proceedings. ITC 2005. IEEE International
  • Conference_Location
    Austin, TX
  • Print_ISBN
    0-7803-9038-5
  • Type

    conf

  • DOI
    10.1109/TEST.2005.1584073
  • Filename
    1584073