• DocumentCode
    3135256
  • Title

    Accurate Theta jc measurement for high power packages

  • Author

    Wan, Qun ; Galloway, Jesse

  • Author_Institution
    Amkor Technol., Chandler, AZ, USA
  • fYear
    2011
  • fDate
    20-24 March 2011
  • Firstpage
    208
  • Lastpage
    215
  • Abstract
    Measuring the case temperature is one of the most challenging measurements for determining the junction-to-case thermal resistance (Theta jc) in high power packages. This is especially true for low Theta jc measurement, in which high power is necessary to control accuracy. Inaccurate case temperature measurement would lead to an inaccurate Theta jc value. This study explores different methods for measuring case temperature and quantifies their impact on Theta jc. A new method of cold-plate protruded thermocouple is proposed and compared with commonly adopted method of lid embedded thermistor both experimentally and numerically. It is found correction is not negligible for low Theta jc measurement in both methods due to the temperature difference between the case surface and the thermal probe location. A standard test jig is also proposed to determine the correction for the cold-plate protruded thermocouple experimentally.
  • Keywords
    power measurement; temperature measurement; thermal resistance; thermal resistance measurement; thermocouples; cold-plate protruded thermocouple; high power packages; lid embedded thermistor; standard test jig; temperature measurement; thermal resistance; Cold plates; Electrical resistance measurement; Heating; Power measurement; Probes; Temperature measurement; Thermistors; Accuracy; Cold plate; Measurement correction; Thermal Test; Thermal resistance; Thermocouple bead; Theta jc; Uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM), 2011 27th Annual IEEE
  • Conference_Location
    San Jose, CA
  • ISSN
    1065-2221
  • Print_ISBN
    978-1-61284-740-5
  • Type

    conf

  • DOI
    10.1109/STHERM.2011.5767202
  • Filename