DocumentCode
3146919
Title
Linear optics calibration at the MIT-Bates South Hall Ring
Author
Wang, E. ; Jacobs, K. ; Carter, A. ; Cheever, D. ; Mcallister, B. ; Sibley, C. ; Safranek, J.
Author_Institution
MIT-Bates Linear Accel. Center, Middleton, MA, USA
Volume
5
fYear
1999
fDate
1999
Firstpage
3101
Abstract
The MIT-Bates South Hall Ring has been successfully commissioned for internal target experiments. More than 150 mA of stored beam has been circulated through a 40 cm long 1.5 cm diameter internal target cell. The ring has also been tuned for the first experiment on an external target using a resonantly extracted high duty factor beam. Beam-based measurements of the ring optics by means of analyzing the beam orbit response matrix, and comparing the results with models, have produced much needed information to set up the ring optics. Efforts have been made to improve the measurement precision, and to put the entire process on-line for use during machine operation
Keywords
calibration; electron accelerators; electron optics; particle beam dynamics; storage rings; 150 mA; MIT-Bates South Hall Ring; beam orbit response matrix; beam-based measurements; internal target cell; internal target experiments; linear optics calibration; machine operation; measurement precision; resonantly extracted high duty factor beam; stored beam; Calibration; Jacobian matrices; Large Hadron Collider; Linear accelerators; Magnets; Optical computing; Optical coupling; Optical sensors; Servomechanisms; Vectors;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1999. Proceedings of the 1999
Conference_Location
New York, NY
Print_ISBN
0-7803-5573-3
Type
conf
DOI
10.1109/PAC.1999.792193
Filename
792193