• DocumentCode
    3150387
  • Title

    Optimized straight CTL cell to calibrate EM field probes in air up to 2.1 GHz

  • Author

    Yun, Jaehoon

  • Author_Institution
    ETRI, Electro-Telecommun. Res. Inst., Daejon
  • Volume
    1
  • fYear
    2003
  • fDate
    16-16 May 2003
  • Firstpage
    115
  • Abstract
    The author describes an optimized straight CTL cell whose uniform area is 2cm times 2cm and field uniformity is plusmn1 dB to calibrate small EM field probes in air. We could obtain the cell with the broadband frequency range up to 2.1 GHz. The field uniformity and frequency range of the cell are compared with those of square type CTL cell and symmetric TEM cell with same test zone in this paper. It is shown that the optimized CTL cell can provide the standard EM fields with broadband frequency range. The measured electric fields and resonant frequencies of the designed CTL cell agree well with the simulated results by moment methods (MM) and variational method (VM) respectively
  • Keywords
    TEM cells; calibration; coupled transmission lines; electric field measurement; electromagnetic compatibility; method of moments; variational techniques; EM field probe calibration; broadband frequency range; cutoff frequency; electric field measurement; field uniformity; moment methods; optimized straight CTL cell; resonant frequencies; square type CTL cell; symmetric TEM cell; variational method; Conductors; Electric variables measurement; Electromagnetic compatibility; Frequency measurement; Moment methods; Probes; Resonant frequency; TEM cells; Testing; Virtual manufacturing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 2003. EMC '03. 2003 IEEE International Symposium on
  • Conference_Location
    Istanbul
  • Print_ISBN
    0-7803-7779-6
  • Type

    conf

  • DOI
    10.1109/ICSMC2.2003.1428208
  • Filename
    1428208