Abstract
The influence caused by the operating wavelength of light source and intersecting angle error of optical axis on measurement accuracy of magnetic optical current transformer (MOCT) are theoretically analyzed and simulated. The investigation results show that the Verdet constant will change because of the fluctuation of the operating wavelength of light source. And angle error of optical axis will lead to direct current and attenuation, which affect measurement accuracy of MOCT. Based on national standard of ECT, the scopes of the operating wavelength of light source and angle error of optical axis are obtained. The results might be useful for researchers and designers working in the MOCT field.
Keywords
Faraday effect; current transformers; light sources; magneto-optical devices; MOCT; Verdet constant; angle error; light source; magnetic optical current transformer; measurement accuracy; operating wavelength; optical axis; Adaptive optics; Current measurement; Optical attenuators; Optical materials; Optical polarization; Optical sensors; Optical variables measurement; MOCT; Verdet constant; intersecting angle error of optical axis; operating wavelength of light source;
fLanguage
English
Publisher
ieee
Conference_Titel
Consumer Electronics, Communications and Networks (CECNet), 2011 International Conference on
Conference_Location
XianNing
Print_ISBN
978-1-61284-458-9
Type
conf
DOI
10.1109/CECNET.2011.5768613
Filename
5768613
Link To Document