• DocumentCode
    3155776
  • Title

    Measurement accuracy study of operating wavelength and angle error of optical axis of MOCT

  • Author

    Ying, Shao ; Xiaoming, Li ; Hao, Chen

  • Author_Institution
    Sch. of Electr. Eng., Wuhan Univ., Wuhan, China
  • fYear
    2011
  • fDate
    16-18 April 2011
  • Firstpage
    5035
  • Lastpage
    5038
  • Abstract
    The influence caused by the operating wavelength of light source and intersecting angle error of optical axis on measurement accuracy of magnetic optical current transformer (MOCT) are theoretically analyzed and simulated. The investigation results show that the Verdet constant will change because of the fluctuation of the operating wavelength of light source. And angle error of optical axis will lead to direct current and attenuation, which affect measurement accuracy of MOCT. Based on national standard of ECT, the scopes of the operating wavelength of light source and angle error of optical axis are obtained. The results might be useful for researchers and designers working in the MOCT field.
  • Keywords
    Faraday effect; current transformers; light sources; magneto-optical devices; MOCT; Verdet constant; angle error; light source; magnetic optical current transformer; measurement accuracy; operating wavelength; optical axis; Adaptive optics; Current measurement; Optical attenuators; Optical materials; Optical polarization; Optical sensors; Optical variables measurement; MOCT; Verdet constant; intersecting angle error of optical axis; operating wavelength of light source;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Consumer Electronics, Communications and Networks (CECNet), 2011 International Conference on
  • Conference_Location
    XianNing
  • Print_ISBN
    978-1-61284-458-9
  • Type

    conf

  • DOI
    10.1109/CECNET.2011.5768613
  • Filename
    5768613