• DocumentCode
    3159471
  • Title

    Remote wireless health monitoring systems

  • Author

    Priya, B. ; Rajendran, S. ; Bala, R. ; Gobbi, R.

  • Author_Institution
    Fac. of Eng., Univ. Ind. Selangor, Bestari Jaya, Malaysia
  • fYear
    2009
  • fDate
    25-26 July 2009
  • Firstpage
    383
  • Lastpage
    388
  • Abstract
    Mobile phone technology has advanced in recent year. Many innovative applications with mobile phones were implemented apart from the conventional voice data transfer. Short message service (SMS) originally developed for sending status information by the service providers have found numerous applications recently including business transactions. In this project, a prototype of a wireless health monitoring system capable of sending SMS related to the health status of the patient is developed. The project can be divided in to three stages of data acquisition, data processing and communication stages. A data acquisition stage consists of sensors to monitor the temperature and pulse rate. The sensor outputs are converted to digital form and read by a Basic Stamp microcontroller which does some processing and is sent through the serial port to the Visual BasicTM data processing software. Various GUI forms like patient information are developed in Visual Basic to assist in data processing. Critical values of the measured data can be set; exceeding which the Visual Basic will initiate the communication unit to send SMS to the predefined mobile numbers. When anomalies are detected or a threshold is reached, the monitoring system automatically transmits the information to the doctor´s hand phone on the mobile network as a SMS message via a GSM device / SMS gateway and at the same time the system will update the hospital database periodically. For each stages of the project various design options were considered and the best one is chosen. The project was successful as a prototype to send SMS regarding the patient info to the doctors. Since only a prototype was intended in this project, sensors accuracy and other data acquisition features were compromised by choosing or simulating the available sensor rather than using biomedical sensors due to cost and availability factors.
  • Keywords
    Visual BASIC; biomedical communication; biosensors; cellular radio; data acquisition; electronic messaging; graphical user interfaces; health care; microcontrollers; mobile radio; patient monitoring; temperature measurement; Basic Stamp microcontroller; GSM device; GUI; Visual Basic data processing software; business transactions; communication stage; data acquisition stage; data processing stage; hospital database; mobile network; mobile phone technology; patient health status; patient information; pulse rate monitoring; remote wireless health monitoring systems; sensors; serial port; short message service gateway; temperature monitoring; Biosensors; Data acquisition; Data processing; Mobile handsets; Patient monitoring; Prototypes; Remote monitoring; Sensor phenomena and characterization; Temperature sensors; Visual BASIC;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Innovative Technologies in Intelligent Systems and Industrial Applications, 2009. CITISIA 2009
  • Conference_Location
    Monash
  • Print_ISBN
    978-1-4244-2886-1
  • Electronic_ISBN
    978-1-4244-2887-8
  • Type

    conf

  • DOI
    10.1109/CITISIA.2009.5224177
  • Filename
    5224177