• DocumentCode
    3170703
  • Title

    Experimental study: brachial motion artifact reduction in the ECG

  • Author

    Luo, Shen ; Tompkins, Willis J.

  • Author_Institution
    Burdick Inc., USA
  • fYear
    1995
  • fDate
    10-13 Sep 1995
  • Firstpage
    33
  • Lastpage
    36
  • Abstract
    This study focuses on a dual-input adaptive noise reduction technique by investigation of brachial motion artifact in the ECG under a special experimental protocol. The ECG and motion artifact signals are acquired from a three-electrode system. Primary input is obtained from the standard EGG lead II. Because limbs function like fixed resistors in ECG measurement, we obtain EGG-free brachial motion noise between two electrodes located on the arm, near the right biceps muscle. The separation distance of the electrodes is 5 mm to acquire the motion noise signal, and this signal is the auxiliary input for adaptive filtering. The results show that the LMS algorithm has a very slow rate of convergence. Comparatively, an RLS algorithm converges almost immediately once motion artifact appears and performs satisfactorily in reducing even rapidly varying brachial artifact. It also significantly improves the low-frequency baseline drift. Although the RLS algorithm imposes a large computational burden, a 33-MHz PC486 can execute the algorithm, written in C language, in real time. To prevent the ill-conditioning matrix in the RLS algorithm when the noise is very small, we add white noise to the auxiliary input The experiment shows that this approach can significantly improve the condition of the matrix
  • Keywords
    adaptive signal processing; electrocardiography; electromyography; least mean squares methods; least squares approximations; medical signal processing; recursive estimation; white noise; 33 MHz; 33-MHz PC486; 5 mm; C language; ECG; LMS algorithm; RLS algorithm; adaptive filtering; arm; brachial motion artifact reduction; convergence; dual-input adaptive noise reduction technique; electrodes; fixed resistors; limbs; low-frequency baseline drift; motion noise signal; real time; right biceps muscle; standard EGG lead II; three-electrode system; white noise; Brachytherapy; Electrocardiography; Electrodes; Measurement standards; Motion measurement; Noise measurement; Noise reduction; Protocols; Resistors; Resonance light scattering;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computers in Cardiology 1995
  • Conference_Location
    Vienna
  • Print_ISBN
    0-7803-3053-6
  • Type

    conf

  • DOI
    10.1109/CIC.1995.482564
  • Filename
    482564