DocumentCode
3201368
Title
Tevatron Beam Lifetimes at Injection Using the Shot Data Analysis System
Author
Xiao, A. ; Bolshakov, T. ; Lebrun, P. ; McCrory, E. ; Papadimitriou, V. ; Slaughter, A.J.
Author_Institution
FNAL, Batavia, IL 60510, U.S.A., xiaoam@fnal.gov
fYear
2005
fDate
16-20 May 2005
Firstpage
1279
Lastpage
1281
Abstract
The purpose of the Shot Data Acquisition and Analysis (SDA) system is to provide summary data on the Fermilab RunII accelerator complex and provide related software for detailed analyses. In this paper, we discuss such a specific analysis on Tevatron beam lifetimes at injection. These results are based on SDA data, tools and methodology. Beam lifetime is one of our most important diagnostics. An analysis of it can give information on intra beam scattering, aperture limitations, instabilities and most importantly beam-beam effects. Such an analysis gives us a better understanding of our machine, and will lead to an improved performance in the future.
Keywords
Apertures; Data acquisition; Data analysis; Extraterrestrial measurements; Forging; Information analysis; Performance analysis; Protons; Radio frequency; Scattering;