• DocumentCode
    3203178
  • Title

    Using Time Separation of Signals to Obtain Independent Proton and Antiproton Beam Position Measurements Around the Tevatron

  • Author

    Webber, R.

  • Author_Institution
    Fermilab, Batavia, IL 60510, U.S.A.
  • fYear
    2005
  • fDate
    16-20 May 2005
  • Firstpage
    1557
  • Lastpage
    1559
  • Abstract
    Independent position measurement of the counter-circulating proton and antiproton beams in the Tevatron, never supported by the original Tevatron Beam Position Monitor (BPM) system, presents a challenge to upgrading that system. This paper discusses the possibilities and complications of using time separation of proton and antiproton signals at the numerous BPM locations and for the dynamic Tevatron operating conditions. Results of measurements using one such method are presented.
  • Keywords
    Colliding beam devices; Extraterrestrial measurements; Forging; Particle beam measurements; Particle beams; Position measurement; Protons; Stripline; Time measurement; Timing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
  • Print_ISBN
    0-7803-8859-3
  • Type

    conf

  • DOI
    10.1109/PAC.2005.1590834
  • Filename
    1590834