DocumentCode
3203178
Title
Using Time Separation of Signals to Obtain Independent Proton and Antiproton Beam Position Measurements Around the Tevatron
Author
Webber, R.
Author_Institution
Fermilab, Batavia, IL 60510, U.S.A.
fYear
2005
fDate
16-20 May 2005
Firstpage
1557
Lastpage
1559
Abstract
Independent position measurement of the counter-circulating proton and antiproton beams in the Tevatron, never supported by the original Tevatron Beam Position Monitor (BPM) system, presents a challenge to upgrading that system. This paper discusses the possibilities and complications of using time separation of proton and antiproton signals at the numerous BPM locations and for the dynamic Tevatron operating conditions. Results of measurements using one such method are presented.
Keywords
Colliding beam devices; Extraterrestrial measurements; Forging; Particle beam measurements; Particle beams; Position measurement; Protons; Stripline; Time measurement; Timing;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN
0-7803-8859-3
Type
conf
DOI
10.1109/PAC.2005.1590834
Filename
1590834
Link To Document