DocumentCode
3205395
Title
Improving the Tevatron Collision Helix
Author
Moore, R.S. ; Alexahin, Y. ; Johnstone, J. ; Sen, T.
Author_Institution
Fermi National Accelerator Laboratory, Batavia, IL 60510, U.S.A.
fYear
2005
fDate
16-20 May 2005
Firstpage
1931
Lastpage
1933
Abstract
In the Tevatron, protons and antiprotons circulate in a single beam pipe, so electrostatic separators are used to create helical orbits that keep the two beams separated except at the two interaction points (IP). Increasing the separation outside of the IPs is desirable in order to decrease long range beam-beam effects during high energy physics (HEP) stores. We can increase separation by running the separators at higher gradients or by installing additional separators. We are pursuing both strategies in parallel. Here, we describe Tevatron operation with higher separator gradients and with new separators installed during a recent shutdown. We also describe possible future installations.
Keywords
Colliding beam accelerators; Data mining; Electrodes; Electrostatics; Laboratories; Orbits; Particle beams; Particle separators; Physics; Proton accelerators;