• DocumentCode
    3216178
  • Title

    Fully Coupled Analysis of Orbit Response Matrices at the FNAL Tevatron

  • Author

    Sajaev, V. ; Lebedev, V. ; Nagaslaev, V. ; Valishev, V.

  • Author_Institution
    ANL, Argonne, IL 60439, U.S.A., sajaev@aps.anl.gov
  • fYear
    2005
  • fDate
    16-20 May 2005
  • Firstpage
    3662
  • Lastpage
    3664
  • Abstract
    Optics measurements have played an important role in improving the performance of the Fermi National Accelerator Laboratory (FNAL) Tevatron collider. Initial optics measurements were performed using a small number of differential orbits, which allowed us to carry out the first round of optics corrections. However, because of insufficient accuracy, it was decided to apply the response matrix analysis method for further optics improvements. The response matrix program developed at Argonne National Laboratory (ANL) has been expanded to include coupling – the essential feature required to describe the Tevatron optics. The results of the optics calibration are presented and compared to local beta function measurements.
  • Keywords
    Calibration; Data processing; Extraterrestrial measurements; Laboratories; Matrix converters; Motion analysis; Orbital calculations; Performance evaluation; Position measurement; Storage rings;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
  • Print_ISBN
    0-7803-8859-3
  • Type

    conf

  • DOI
    10.1109/PAC.2005.1591573
  • Filename
    1591573