DocumentCode
3220056
Title
Behavior of metal oxide based varistors subjected to partial discharges in air
Author
Kourdi, M.B. ; Bui, A. ; Loubiere, A. ; Khedim, A.
Author_Institution
Lab. de Genie Electr., Univ. Paul Sabatier, Toulouse, France
fYear
1992
fDate
22-25 Jun 1992
Firstpage
265
Lastpage
269
Abstract
Experimental results are presented on the degradation of ZnO varistors under the action of partial discharges. The degradation observed is a corrosion of the insulating materials, giving rise to an increase of the surface resistivity. The conducting deposit is probably produced by chemical reaction of the oxide surface with the nitric acid formed by electrical discharge in humid air. In this acid, the strong corrosion of uncoated varistors is more pronounced than in glass or resin coated ones. Degradation is strongly influenced by the level of discharge energy. The increase in the surface conductivity could, in service, give rise to high temperatures and consequently to the risk of a thermal runaway and to a premature aging of varistors. It is concluded that the quality of the insulating coating around the varistors used in surge arresters for the protection of medium- and high-voltage power lines should be improved
Keywords
ageing; partial discharges; surge protection; varistors; zinc compounds; ZnO; chemical reaction; conducting deposit; corrosion; discharge energy; electrical discharge; humid air; metal oxide based varistors; partial discharges; power lines; premature aging; surface conductivity; surface resistivity; surge arresters; thermal runaway; Chemicals; Conducting materials; Corrosion; Degradation; Insulation; Partial discharges; Surface discharges; Thermal conductivity; Varistors; Zinc oxide;
fLanguage
English
Publisher
ieee
Conference_Titel
Conduction and Breakdown in Solid Dielectrics, 1992., Proceedings of the 4th International Conference on
Conference_Location
Sestri Levante
Print_ISBN
0-7803-0129-3
Type
conf
DOI
10.1109/ICSD.1992.224942
Filename
224942