• DocumentCode
    3228914
  • Title

    Diagnosis of HV stator bars insulation in the presence of multi partial-discharge phenomena

  • Author

    Contin, A. ; Fenu, G.F. ; Parisini, T.

  • Author_Institution
    Dipt. di Elettrotecnica Elettronica ed Inf., Trieste Univ., Italy
  • Volume
    2
  • fYear
    1996
  • fDate
    20-23 Oct 1996
  • Firstpage
    488
  • Abstract
    Results of Partial Discharge (PD) measurements, performed on insulation system of rotating machines, are processed referring to the Weibull statistics. Probability functions based on the additive-mixed Weibull distribution are used to fit experimental data obtained in the presence of PD phenomena of different types, simultaneously active. A non-parametric Kernel Regression technique is adopted to pre-process the experimental data in order to determine the number of components and the basic characteristics of the mixed distribution. A tree structure for the PD phenomena clustering, particularly useful to monitor the time and/or voltage behavior of multi-PD phenomena, is proposed
  • Keywords
    Weibull distribution; insulation testing; machine insulation; machine testing; partial discharges; stators; trees (electrical); HV stator bars insulation; Weibull statistics; additive-mixed Weibull distribution; multi partial-discharge phenomena; nonparametric kernel regression technique; probability functions; rotating machines; tree structure; voltage behavior; Insulation; Partial discharge measurement; Partial discharges; Performance evaluation; Probability; Rotating machines; Rotation measurement; Statistical distributions; Stator bars; Weibull distribution;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena, 1996., IEEE 1996 Annual Report of the Conference on
  • Conference_Location
    Millbrae, CA
  • Print_ISBN
    0-7803-3580-5
  • Type

    conf

  • DOI
    10.1109/CEIDP.1996.564516
  • Filename
    564516