DocumentCode
3230741
Title
High frame rate echocardiography using diverging beams
Author
Hasegawa, Hideyuki ; Kanai, Hiroshi
Author_Institution
Grad. Sch. of Biomed. Eng., Tohoku Univ., Sendai, Japan
fYear
2011
fDate
18-21 Oct. 2011
Firstpage
132
Lastpage
135
Abstract
Echocardiography is a widely-used modality for diagnosis of the heart. It enables observation of the shape of a heart and estimation of global heart function based on B-mode and M-mode imaging. Subsequently, methods for estimating myocardial strain and strain rate have been developed to evaluate regional heart function. Furthermore, it has been recently shown that measurements of transmural transition of myocardial contraction/relaxation and propagation of vibration caused by closure of a heart valve would be useful for evaluation of myocardial function and viscoelasticity. However, such measurements require a frame rate much higher than that achieved by conventional ultrasonic diagnostic equipment. In the present study, a method based on parallel receive beamforming using diverging waves in transmit was developed to achieve high-frame-rate echocardiography over 300 Hz. The spatial resolution of the proposed method was validated using fine nylon wires. Although the widths at half maxima of the point spread functions obtained by diverging waves were slightly larger than those obtained by conventional beamforming and parallel beamforming with plane waves, the point spread functions, which were very similar to that obtained by conventional beamforming could be realized by parallel beamforming with diverging beams and compounding. Furthermore, a heart of a 23-year-old healthy male was measured, and a frame rate of 316 Hz, which was much higher than that realized by conventional sector scanning of several tens of Hertz, was realized with a full lateral field of view of 90 degrees.
Keywords
biomechanics; biomedical equipment; biomedical measurement; echocardiography; optical transfer function; viscoelasticity; B-mode imaging; M-mode imaging; age 23 yr; conventional beamforming diverging beams; conventional beamforming plane waves; conventional sector scanning; conventional ultrasonic diagnostic equipment; fine nylon wires; frequency 316 Hz; global heart function; high frame rate echocardiography; myocardial contraction-relaxation; myocardial function; parallel beamforming diverging beams; parallel beamforming plane waves; point spread functions; spatial resolution; transmural transition; vibration propagation; viscoelasticity; Acoustics; Array signal processing; Heart; Imaging; Myocardium; Radio frequency; Ultrasonic imaging;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium (IUS), 2011 IEEE International
Conference_Location
Orlando, FL
ISSN
1948-5719
Print_ISBN
978-1-4577-1253-1
Type
conf
DOI
10.1109/ULTSYM.2011.0033
Filename
6293452