• DocumentCode
    323244
  • Title

    Multi-element CdZnTe detectors for gamma ray detection and imaging

  • Author

    Bennett, P.R. ; Shah, K.S. ; Cirignano, L.J. ; Klugerman, M.B. ; Dmitryev, Y.N. ; Squillante, M.R.

  • Author_Institution
    Radiat. Monitoring Devices Inc., Watertown, MA, USA
  • fYear
    1997
  • fDate
    9-15 Nov 1997
  • Firstpage
    561
  • Abstract
    A small pixellated gamma-ray detector has been constructed from a 5 mm thick CdZnTe substrate and characterized for spectroscopic and spatial properties. Emphasis has been placed on revealing `pixel-level´ results to further understand optimum array design and operation. The anode design is (1.5×1.5) mm2 pixels on a 1.625 mm pitch. Spectroscopic results with a 57Co source display an average energy resolution of 3.9 keV FWHM. Analysis of the electronic noise for different pixels showed good agreement with a theoretical model and similar performance between edge and interior pixels. A test of spatial response with scanned sources incident on the anode face showed good agreement with the pixel geometry and an undetectable amount of dependence on interaction depth
  • Keywords
    gamma-ray detection; gamma-ray spectrometers; position sensitive particle detectors; semiconductor counters; semiconductor device noise; 5 mm; CdZnTe; CdZnTe detectors; anode design; electronic noise; energy resolution; interaction depth; pixellated gamma-ray detector; pixels; spatial response; Anodes; Displays; Energy resolution; Gamma ray detection; Gamma ray detectors; Geometry; Optical imaging; Performance analysis; Spectroscopy; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium, 1997. IEEE
  • Conference_Location
    Albuquerque, NM
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-4258-5
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1997.672645
  • Filename
    672645