• DocumentCode
    3235332
  • Title

    Estimation and display for Vector Doppler Imaging using planewave transmissions

  • Author

    Flynn, John ; Daigle, Ron ; Pflugrath, Lauren ; Linkhart, Ken ; Kaczkowski, Peter

  • Author_Institution
    Verasonics, Inc., Redmond, WA, USA
  • fYear
    2011
  • fDate
    18-21 Oct. 2011
  • Firstpage
    413
  • Lastpage
    418
  • Abstract
    Vector Doppler Imaging (VDI) reveals the blood flow velocity vector at each pixel. We present a multiple-angle planewave transmission (PWT) scheme that enables vector velocity imaging at a high frame-rate. The method employs a fast, aliasing-resistant velocity vector estimator and captures transitory flow dynamics, as demonstrated on a carotid artery with a 5 MHz linear array using a novel synthetic particle flow visualization method. Conventional color Doppler processing applied to several PWT angles produces a set of Doppler images. These are combined into a small weighted least squares (WLS) problem for each pixel, conditioned for bias due to aliasing. Weights account for signal quality at each PWT angle. The WLS covariance provides metrics to qualify pixels. To visualize the resulting velocity vector image, we use a novel technique which synthesizes a moving field of points representing particles entrained in the fluid. Each particle is generated by Bernoulli trial at detected flow pixels, and given motion by the velocity vector estimate. The motion is scaled down so the viewer may easily perceive flow in “real-time slow-motion”. Particles migrate across the image from frame to frame, under conservation rules mimicking fluid flow. The user controls displayed density of particles that overlay the detected flow regions, which are color-coded for velocity magnitude. Using a Verasonics VDAS acquisition system and a Philips L7-4 transducer, we demonstrate in vivo VDI on neck vasculature. PWT ensembles collected at seven angles are processed with the VDI algorithm giving an imaging rate of 30 fps. Video display reveals dynamics of the flow field and shows good detection of flow during diastole.
  • Keywords
    Doppler measurement; biomedical transducers; biomedical ultrasonics; blood vessels; flow; haemodynamics; image resolution; least mean squares methods; medical image processing; Bernoulli trial; PWT scheme; Philips L7-4 transducer; VDI algorithm; WLS problem; aliasing-resistant velocity vector estimator; blood flow velocity vector; carotid artery; conventional color Doppler processing; display estimation; frequency 5 MHz; linear array; multiple-angle planewave transmission scheme; real-time slow-motion; small weighted least squares problem; synthetic particle flow visualization method; transitory flow dynamics; vector Doppler imaging; verasonics VDAS acquisition system; video display; Correlation; Doppler effect; Estimation; Frequency estimation; Imaging; Vectors; Visualization;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2011 IEEE International
  • Conference_Location
    Orlando, FL
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4577-1253-1
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2011.0099
  • Filename
    6293682