DocumentCode
3258096
Title
Partial discharge inception characteristic and charge behavior for magnet wire under repetitive inverter surge voltage condition
Author
Shimizu, F. ; Nakamura, Y. ; Inano, H. ; Hayakawa, N. ; Okubo, H.
Author_Institution
Nagoya Univ., Nagoya
fYear
2008
fDate
7-11 Sept. 2008
Firstpage
629
Lastpage
632
Abstract
In this paper, we discussed partial discharge (PD) inception characteristics and mechanisms of magnet wires for inverter-fed motor under repetitive surge voltage application. Experimental results revealed the relationship between PD inception voltage (PDIV) and parameters of applied surge voltage waveform. The relationship between PD pulses and repetitive surge voltage pulses was also investigated. PD generation mechanisms were discussed from the view point of charge behavior in the wedge-shaped air gap and on the enamel surface.
Keywords
invertors; partial discharge measurement; surface charging; surge protection; charge behavior; inverter-fed motor; magnet wire; partial discharge inception characteristic; repetitive inverter surge voltage condition; Inverters; Partial discharges; Surges; Voltage; Wire;