DocumentCode
3264664
Title
An Algorithm for Recovering FECG Signal
Author
Li, Yunxia ; Fan, Changyuan ; Zhang, Jianglin
Author_Institution
Sch. of Autom. Eng., Univ. of Electron. Sci. & Technol. of China, Chengdu
Volume
1
fYear
2006
fDate
25-28 June 2006
Firstpage
422
Lastpage
424
Abstract
The extraction of fetal electrocardiogram (FECG) from the composite maternal ECG signal is discussed. This problem can be modelled from the perspective of blind source extraction. Using the objective function presented by Barros, this paper proposes a new algorithm to extract the FECG with higher speed. Simulation results confirm the validity of the proposed algorithm
Keywords
blind source separation; electrocardiography; FECG; blind source extraction; composite maternal ECG signal; fetal electrocardiogram; signal recovery algorithm; Additive noise; Autocorrelation; Automation; Biomedical electrodes; Data mining; Electrocardiography; Heart beat; Noise cancellation; Signal processing algorithms; Source separation;
fLanguage
English
Publisher
ieee
Conference_Titel
Communications, Circuits and Systems Proceedings, 2006 International Conference on
Conference_Location
Guilin
Print_ISBN
0-7803-9584-0
Electronic_ISBN
0-7803-9585-9
Type
conf
DOI
10.1109/ICCCAS.2006.284667
Filename
4063911
Link To Document