• DocumentCode
    3284205
  • Title

    Leakage detecting and localizing for gas pipeline based on pressure time series

  • Author

    Junru, Wang ; Tao, Wang

  • Author_Institution
    Dept. of Autom., Beijing Inst. of Technol., Beijing, China
  • fYear
    2011
  • fDate
    15-17 April 2011
  • Firstpage
    4256
  • Lastpage
    4259
  • Abstract
    Because of the low accuracy and destroying the pipeline original flow of the flow-meter installation, this paper introduced a method of leakage detection and localization for gas pipeline based on pressure time series. During the detection, only pressure was collected. The location and leakage information were obtained according the pressure detection of different position. The experiment indicated the method could accomplish the higher accuracy detection and location for gas pipeline.
  • Keywords
    flowmeters; leak detection; pipelines; time series; flow-meter installation; gas pipeline; leakage detecting; leakage localizing; pipeline original flow; pressure time series; Accuracy; Artificial neural networks; Automation; Leak detection; Pipelines; Safety; Time series analysis; leakage detection; location; neural network; pressure time series;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electric Information and Control Engineering (ICEICE), 2011 International Conference on
  • Conference_Location
    Wuhan
  • Print_ISBN
    978-1-4244-8036-4
  • Type

    conf

  • DOI
    10.1109/ICEICE.2011.5777803
  • Filename
    5777803