DocumentCode
3295691
Title
Failure analysis of process-induced particle contamination acting as masks that block implantation using C-AFM and chemical etching
Author
Lin, Hung Sung ; Wang, Randy
Author_Institution
United Microelectron. Corp., Ltd., Hsinchu, Taiwan
fYear
2009
fDate
6-10 July 2009
Firstpage
59
Lastpage
62
Abstract
Ion implantation is one of the most common steps in the manufacture of integrated circuits. The characterization and visualization of process-induced particle contamination acting as masks that block implantation especially when the defects are not in a specific area of a chip takes a lot of effort. This paper describes the use of a Conductive Atomic Force Microscope (C-AFM) technique coupled with wet chemical etching analysis to quickly make different implants visible at low cost.
Keywords
atomic force microscopy; etching; integrated circuit manufacture; ion implantation; C-AFM; conductive atomic force microscope; failure analysis; integrated circuit manufacture; ion implantation; mask; process-induced particle contamination; wet chemical etching analysis; Atomic force microscopy; Chemical analysis; Chemical processes; Contamination; Coupling circuits; Etching; Failure analysis; Integrated circuit manufacture; Ion implantation; Visualization;
fLanguage
English
Publisher
ieee
Conference_Titel
Physical and Failure Analysis of Integrated Circuits, 2009. IPFA 2009. 16th IEEE International Symposium on the
Conference_Location
Suzhou, Jiangsu
ISSN
1946-1542
Print_ISBN
978-1-4244-3911-9
Electronic_ISBN
1946-1542
Type
conf
DOI
10.1109/IPFA.2009.5232697