• DocumentCode
    3296686
  • Title

    Investigation of the block effect in LSO detectors

  • Author

    James, Sara T St ; Thompson, Christopher J.

  • Author_Institution
    Dept. of Radiat. Oncology, Centre Hospitalier des Valees d´´Outaouis, Gatineau, Que.
  • Volume
    5
  • fYear
    2005
  • fDate
    23-29 Oct. 2005
  • Firstpage
    2474
  • Lastpage
    2477
  • Abstract
    The block effect is the degradation in spatial resolution that exists when there are more scintillation crystals than photomultiplier tubes in a PET detector. In this study the block effect was measured for the Siemens-CTI Hi-Rez PET detector, a LSO block detector. The effect of changing gamma-ray interaction depth in the scintillation crystals in the Hi-Rez detector was also examined. These results are compared to results obtained with two BGO PET detectors; the Siemens-CTI HR+ and the GE Advance. The magnitude of the block effect in the central three crystal columns of the Hi-Rez detector was found to be negligible, while the magnitude of the block effect varied from 0.6 mm to 2.9 mm in the remaining crystal columns. Events that occurred at different crystal depths were decoded consistently in the central three crystal columns, and inconsistently in the remaining crystal columns. Previously, we found that the block effect was 0.9 mm in the GE Advance block detector, negligible for the edge crystals in the CTI HR+ block detector, and averaged 1.2 mm in the center crystals of the CTI HR+ block detector. In the GE Advance detector, events that occurred at different crystal depths were decoded consistently. In the CTI HR+ block detector, events that occurred deeper in the crystal had a greater probability of being positioned inaccurately. The results from the three detectors examined suggest that the inconsistent positioning of events that occur at different crystal depths contribute to the block effect, in both LSO and BGO block detectors
  • Keywords
    positron emission tomography; solid scintillation detectors; BGO PET detectors; GE Advance block detector; LSO detectors; Siemens-CTI HR+ block detector; Siemens-CTI Hi-Rez PET detector; block effect; gamma-ray interaction depth; photomultiplier tubes; scintillation crystals; spatial resolution; Crystals; Decoding; Degradation; Event detection; Gamma ray detection; Gamma ray detectors; Photomultipliers; Positron emission tomography; Solid scintillation detectors; Spatial resolution;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2005 IEEE
  • Conference_Location
    Fajardo
  • ISSN
    1095-7863
  • Print_ISBN
    0-7803-9221-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2005.1596842
  • Filename
    1596842