Abstract
We have been developing a new type of neutron imaging detector with position resolution better than 10 micrometer by absorbing liquid scintillator for neutron capture into a capillary plate by capillary phenomena. Establishing the methods to absorb liquid scintillator to the capillary plate and attaching it into a photomultiplier, we irradiated the detector with neutrons and alpha particles. From the results of basic experiments, it was recognized that the capillary plate absorbing liquid scintillator can operate as a neutron detector
Keywords
alpha-particle detection; liquid scintillation detectors; neutron detection; photomultipliers; alpha particles; capillary plate absorbing liquid scintillator; neutron imaging detector; photomultiplier; Alpha particles; Energy resolution; Glass; High-resolution imaging; Image resolution; Manufacturing; Neutrons; Optical detectors; Optical devices; Timing;