DocumentCode
3313185
Title
Research on multi-channel smoke screen infrared transmittance measurement
Author
Gao, Lixin ; Wang, Qi ; Xiong, Luyuan ; Bao, Jian ; Wang, Jinzu
Author_Institution
Anhui Inst. of Opt. & Fine Mech., Chinese Acad. of Sci., Hefei, China
fYear
2009
fDate
8-11 Aug. 2009
Firstpage
578
Lastpage
581
Abstract
A multi-channel scan measurement instrument designed for characterizing the infrared obscuring performance of smoke screen at the wavelength of 10.6 mum is developed. It offers 1 to 5 sensors for multi points real time measurements of infrared transmissivity in the field. Data transmission is accomplished by wireless communication. The maximum detection range of the instrument is 500 meters with measurement accuracy better than plusmn 5%.
Keywords
data communication; radiocommunication; smoke detectors; infrared obscuring performance; infrared transmissivity; multichannel scan measurement instrument; multichannel smoke screen infrared transmittance measurement; wavelength 10.6 mum; wireless communication; Area measurement; Extinction coefficients; Infrared detectors; Instruments; Laser beams; Laser modes; Optical attenuators; Smoke detectors; Thickness measurement; Wavelength measurement; infrared radiation; smoke screen; transmissivity; wireless communication;
fLanguage
English
Publisher
ieee
Conference_Titel
Computer Science and Information Technology, 2009. ICCSIT 2009. 2nd IEEE International Conference on
Conference_Location
Beijing
Print_ISBN
978-1-4244-4519-6
Electronic_ISBN
978-1-4244-4520-2
Type
conf
DOI
10.1109/ICCSIT.2009.5234628
Filename
5234628
Link To Document