DocumentCode
3315789
Title
Evaluation of thermal junction quality in thermoelectric assemblies using transient analysis technology
Author
Ritzer, Todd M. ; Nagy, Michael J. ; Buist, Richard J.
Author_Institution
TE Technol. Inc., Traverse lify, MI, USA
fYear
1996
fDate
26-29 March 1996
Firstpage
293
Lastpage
297
Abstract
This paper describes the application of the transient analysis test method to evaluate the integrity of thermal junctions in a thermoelectric (TE) assembly. The quality of thermal junctions in assemblies was measured by creating a thermal gradient in the TE modules comprising an assembly and analyzing the decay of the residual Seebeck voltage. A study was made of various junction conditions that exist between the TE module and its heatsinks which are common to most assembly techniques. Poor thermal contacts were deliberately introduced such as insufficient thermal grease, inadequate compression and improper surface finishes in test assemblies in order to simulate typical assembly defects. A direct correlation between good and inadequate thermal junctions was established and illustrated through graphic test data evaluation.
Keywords
heat exchangers; heat sinks; thermal analysis; thermoelectric conversion; thermoelectric devices; transient analysis; assembly defects; graphic test data evaluation; heat sinks; residual Seebeck voltage decay; surface finish; thermal contacts; thermal gradient; thermal grease; thermal junction quality; thermoelectric heat exchanger assemblies; transient analysis test method; Assembly; Heat sinks; Pollution measurement; Rough surfaces; Surface roughness; Tellurium; Testing; Thermoelectricity; Transient analysis; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Thermoelectrics, 1996., Fifteenth International Conference on
Conference_Location
Pasadena, CA, USA
Print_ISBN
0-7803-3221-0
Type
conf
DOI
10.1109/ICT.1996.553320
Filename
553320