• DocumentCode
    3322617
  • Title

    HYBUD: An Energy-Efficient Architecture for Hybrid Parallel Disk Systems

  • Author

    Nijim, Mais ; Manzanares, Adam ; Ruan, Xiaojun ; Qin, Xiao

  • Author_Institution
    Sch. of Comput., Univ. of Southern Mississippi, Hattiesburg, MS, USA
  • fYear
    2009
  • fDate
    3-6 Aug. 2009
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    In the past decade parallel disk systems have been highly scalable and able to alleviate the problem of disk I/O bottleneck, thereby being widely used to support a wide range of data-intensive applications. Optimizing energy consumption in parallel disk systems has strong impacts on the cost of backup power-generation and cooling equipment, because a significant fraction of the operation cost of data centres is incurred by energy consumption and cooling. Although flash memory is very energy-efficient compared to disk drives, flash memory is too expensive to use as a major component in large-scale storage systems. In other words, it is not a cost-effective way to make use of large flash memory to build energy-efficient storage systems. To address this problem, in this paper we proposed a hybrid disk architecture or HYBUD that integrates a non-volatile flash memory with buffer disks to build cost-effective and energy-efficient parallel disk systems. While the most popular data sets are cached in flash memory, the second most popular data sets can be stored and retrieved from buffer disks. HYBUD is energy efficient because flash memory coupled with buffer disks can serve a majority of incoming disk requests, thereby keeping a large number of other data disks in the low-power state for longer period times. Furthermore, HYBUD is cost-effective by the virtue of inexpensive buffer disks assisting flash memory to cache a huge amount of popular data. Experimental results demonstratively show that compared with two existing non-hybrid architectures, HYBUD provides significant energy savings for parallel disk systems in a very cost effective way.
  • Keywords
    cache storage; computer centres; energy consumption; flash memories; random-access storage; HYBUD; backup power-generation; buffer disks; cache; cooling equipment; data centres; data-intensive applications; disk I/O bottleneck; energy consumption optimization; energy-efficient architecture; hybrid disk architecture; hybrid parallel disk systems; nonvolatile flash memory; Buffer storage; Cooling; Cost function; Disk drives; Energy consumption; Energy efficiency; Energy storage; Flash memory; Large-scale systems; Nonvolatile memory;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computer Communications and Networks, 2009. ICCCN 2009. Proceedings of 18th Internatonal Conference on
  • Conference_Location
    San Francisco, CA
  • ISSN
    1095-2055
  • Print_ISBN
    978-1-4244-4581-3
  • Electronic_ISBN
    1095-2055
  • Type

    conf

  • DOI
    10.1109/ICCCN.2009.5235264
  • Filename
    5235264