• DocumentCode
    3331215
  • Title

    Notice of Retraction
    Morin-Ce4+ Chemiluminescence for the Determination of Environmental Endocrine Disruptors-Nonylphenol

  • Author

    Yang Yingchun ; Zhang Jingjing ; Ye Zhixiang ; Yin Hongling ; Yi Congshu ; Zhang Lin

  • Author_Institution
    Dept. of Environ. Sci. & Eng., Chengdu Univ. of Inf. Technol., Chengdu, China
  • fYear
    2011
  • fDate
    10-12 May 2011
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Notice of Retraction

    After careful and considered review of the content of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE´s Publication Principles.

    We hereby retract the content of this paper. Reasonable effort should be made to remove all past references to this paper.

    The presenting author of this paper has the option to appeal this decision by contacting TPII@ieee.org.

    A novel flow-injection chemiluminescence(CL) system has been established based on the inhibitory effect of nonylphenol(NP) on the morin-Ce4+ CL system. The flow path, flow rate, concentration of Ce4+, pH of Ce4+ solution and concentration of morin were discussed. The results show that the best determination conditions are 5.0×10-3 mol/L of Ce4+, 1.0×104 mol/L of morin and pH=1.2 of Ce4+ solution. Under the optimal conditions, the reduction value of CL intensity is linear with the concentration of NP within 2×10-8~2×10-7g/ml and 2×10-6~4×10-5 g/ml. The regression equation was Δl1=12.12+225.95CNP and Δl2=65.291+753164.6CNP with correlation coefficient 0.9995 and 0.998, respectively. And the detection limit was 2×10-10 g/ml (3σ). The relative standard deviation (RSD) is 1.48% for the determination of 2×107 g/ml NP(n=10). The recoveries of NP are between 90.7%~106.3% for three different environmental water samples. It suggested that this method can be used for the determination of NP in the real environmental samples.
  • Keywords
    cerium; chemical hazards; chemiluminescence; hazardous materials; inhibitors; organic compounds; pH; water pollution; Ce4+; Ce4+ concentration; Ce4+ solution; correlation coefficient; environmental endocrine disruptors; environmental water samples; flow path; flow rate; flow-injection chemiluminescence system; inhibitory effect; morin concentration; morin-Ce4+ chemiluminescence; nonylphenol; pH; regression equation; relative standard deviation; Chemicals; Instruments; Kinetic theory; Materials; Monitoring; Water pollution;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Bioinformatics and Biomedical Engineering, (iCBBE) 2011 5th International Conference on
  • Conference_Location
    Wuhan
  • ISSN
    2151-7614
  • Print_ISBN
    978-1-4244-5088-6
  • Type

    conf

  • DOI
    10.1109/icbbe.2011.5780741
  • Filename
    5780741