• DocumentCode
    3331634
  • Title

    Empirical cupping correction for CT scanners with tube voltage modulation (ECCU)

  • Author

    Ritschl, Ludwig ; Bergner, Frank ; Fleischmann, Christof ; Kachelriess, Marc

  • Author_Institution
    Inst. of Med. Phys. (IMP), Univ. of Erlangen-Nurnberg, Erlangen, Germany
  • fYear
    2009
  • fDate
    Oct. 24 2009-Nov. 1 2009
  • Firstpage
    3950
  • Lastpage
    9394
  • Abstract
    X-ray CT measures the attenuation of polychromatic x-rays through an object of interest. The CT data aquired are the negative logarithm of the relative x- ray intensity behind the patient. These data must undergo water precorrection to linearize the measured data and convert them into line integrals through the patient that can be reconstructed to yield the final CT image. The function to linearize the measured projection data depends on the tube voltage U. In most circumstances, CT scans are carried out with a constant tube voltage. For those cases there are dozens of different techniques to carry out water precor-rection. In our case the tube voltage is rather modulated as a function of the object. We propose an empirical cupping correction (ECCU) algorithm to correct for CT cupping artifacts that are induced by non-linearities in the projection data. The method is rawdata-based, empirical and does neither require knowledge of the x-ray spectrum nor of the attenuation coefficients. It aims at linearizing the attenuation data using a precorrection function of polynomial form in the polychromatic attenuation data q and in the tube voltage U. The coefficients of the polynomial are determined once using a calibration scan of a homogeneous phantom. Computing the coefficients is done in image domain by fitting a series of basis images to a template image. The template image is obtained directly from the uncorrected phantom image and no assumptions on the phantom size or of its positioning are made. Rawdata are precorrected by passing them through the once-determined polynomial. Numerical examples are shown to demonstrate the quality of the precorrection. ECCU achieves to remove the cupping artifacts and to obtain well-calibrated CT-values. A combination of ECCU with analytical techniques yielding a hybrid cupping correction method is possible and allows for channel-dependent correction functions.
  • Keywords
    computerised tomography; diagnostic radiography; image reconstruction; medical image processing; phantoms; CT scanners; ECCU algorithm; X-ray computerised tomography; empirical cupping correction; image reconstruction; phantoms; polychromatic X-rays; polychromatic attenuation data; relative X-ray intensity; tube voltage modulation; water precorrection; Attenuation; Calibration; Computed tomography; Detectors; Image reconstruction; Imaging phantoms; Polynomials; Q measurement; Voltage; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
  • Conference_Location
    Orlando, FL
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-3961-4
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2009.5401946
  • Filename
    5401946