• DocumentCode
    3331652
  • Title

    Magnetized microplasmas generated in a narrow quartz tube

  • Author

    Yoshiki, H.

  • Author_Institution
    Tsuruoka Nat. Coll. of Technol., Tsuruoka, Japan
  • fYear
    2010
  • fDate
    20-24 June 2010
  • Firstpage
    1
  • Lastpage
    1
  • Abstract
    Recently, several microplasma sources have developed for ga s chromatography detector, nanomaterial synthesis, localized etching and onsite deposition. According to Paschen´s law, microplasmas easily generate at atmospheric pressure becaus e the smaller discharge gap, the higher gas pressure. However, low pressure operation is anticipated to open up a possibility of controlling plasma parameters and radicals in a plasma gas phase. For this purpose, radio frequency (rf) He and Ar microplasmas generated in a narrow quartz tube having an inner diameter of 1 mm (referred to as capillar y microplasmas) have been magnetized by applying the stron g magnetic field, provided that the magnetic field is perpendi cular to both the rfelectric field and the tube axis and that the Larmor radius of an electron is sufficiently smaller than both the electron mean free path and tube inner radius. In this con dition, a rf oscillating EXB drift motion seems to occur along the tube axis. When a magnetic field with a magnetic flux density of 0.4 T was applied, the magnetized capillary microplasma could be generated at gas pressure lower than 1.5 kPa because the electron cyclotron frequency exceeds the electron-neutral collision frequency. The dependence of atomic excitation temperatures on gas pressure for He and Ar microplasmas generated at a constant rf power of 4 W with and without a magnetic field of 0.4 T was studied2. Magnetized capillary microplasmas have generated at low gas pressure of below several kPa. The Ar atomic excitation temperature increased dramatically from 5000K to 15000K when the gas pressure was re duced from 4 to 0.2 kPa. This implies an increase in the electron temperature. In addition, plasma has not ignited without t he strong magnetic field at gas pressures below 2 kPa, even a t rf powers of 10 W or more. Furthermore, Ar ionic emission (Ar II) lines were clearly observed in the spectral range of 43 0-500 nm. It means that an increase in electron te- perature enhances the ionization and excitation efficiencies. Therefore, magnetized capillary microplasmas have the potential to be used as miniaturized ion sources.
  • Keywords
    plasma confinement; plasma sources; Ar ionic emission; Larmor radius; capacitively coupled radio frequency; discharge gap; gas chromatography detector; magnetized capillary microplasmas; microplasma sources; narrow quartz tube; Argon; Atmospheric-pressure plasmas; Detectors; Electron tubes; Frequency; Helium; Magnetic fields; Magnetic flux; Plasma applications; Plasma temperature;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Plasma Science, 2010 Abstracts IEEE International Conference on
  • Conference_Location
    Norfolk, VA
  • ISSN
    0730-9244
  • Print_ISBN
    978-1-4244-5474-7
  • Electronic_ISBN
    0730-9244
  • Type

    conf

  • DOI
    10.1109/PLASMA.2010.5534139
  • Filename
    5534139