• DocumentCode
    3334135
  • Title

    Cyclotron radiometer based on low-cost, successive detection logarithmic amplifier electron

  • Author

    Morales, Cristina ; Rodgers, John

  • Author_Institution
    Florida Int. Univ., Miami, FL, USA
  • fYear
    2010
  • fDate
    20-24 June 2010
  • Firstpage
    1
  • Lastpage
    1
  • Abstract
    A new electron cyclotron emission (ECE) radiometer has been designed, constructed and tested on the Maryland Centrifugal Experiment (MCX) [1]. The receiver was based on the Analog Devices AD8310, which is a successive detection logarithmic amplifier capable of direct RF down-conversion with >95 dB of dynamic range. This integrated circuit was chosen because of its low noise floor, excellent logarithmic accuracy (+/- 0.4 dB) and fast video response (15 ns rise time). The capabilities of this integrated circuit made it possible to design a very low cost ECE radiometer using a minimal number of components but with exceptional performance characteristics. The design, construction and initial testing of the ECE radiometer was performed over the summer of 2009 as an REU research project at the University of Maryland. These instruments have been employed for many years to measure the intensity of blackbody radiation from fusion plasmas, from which the electron temperature can be calculated. Typically, such measurements are made using ECE receivers where the video signal is intentionally filtered to time-average high-frequency, large amplitude fluctuation in the emission due to plasma instabilities. In our case, we utilized the wideband characteristic of the receiver to measure edge modes in the MCX plasma, which rotates at Mach >1. We will present the details about the design of the ECE radiometer and show the results of the measurements. The data show that rapid fluctuations in ECE intensity were well correlated with the optical and magnetic diagnostics on MCX. The results demonstrate that a large array of these receivers could be economically constructed and utilized to perform correlation radiometry on the MCX plasma.
  • Keywords
    plasma devices; plasma instability; radiometers; RF down-conversion; detection logarithmic amplifier; edge modes; electron cyclotron emission radiometer; integrated circuit; magnetic diagnostics; optical diagnostics; plasma instabilities; receiver; video signal; wideband characteristic; Circuit testing; Cyclotrons; Electrons; Optical amplifiers; Optical receivers; Plasma measurements; Plasma properties; Plasma temperature; Radiofrequency amplifiers; Radiometry;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Plasma Science, 2010 Abstracts IEEE International Conference on
  • Conference_Location
    Norfolk, VA
  • ISSN
    0730-9244
  • Print_ISBN
    978-1-4244-5474-7
  • Electronic_ISBN
    0730-9244
  • Type

    conf

  • DOI
    10.1109/PLASMA.2010.5534286
  • Filename
    5534286